Transforms subclinical keratoconus detection, delivering 3x faster in-vivo corneal biomechanical mapping.

This technology uses fast, high-precision 3D Brillouin microscopy with advanced motion tracking and accurate calibration to create detailed maps of corneal biomechanics, enabling early detection of conditions like keratoconus and improved monitoring after eye surgery.

Background

The cornea’s structural integrity is essential for maintaining the eye’s shape and ensuring clear vision. When these biomechanical properties deteriorate, it leads to debilitating disorders like keratoconus, causing the cornea to thin, warp, and severely impair focus. To prevent irreversible visual damage, clinicians need a reliable way to assess the physical strength of the eye’s surface before symptoms advance. Therefore, there is a critical medical need to accurately measure and map corneal biomechanics in living patients to enable the early diagnosis of degenerative eye conditions.

Despite this need, current diagnostic tools have major limitations. Standard commercial devices use an air puff to deform the eye, measuring the entire eye’s reaction rather than just the cornea. Their results are skewed by baseline eye pressure and tissue thickness, and they cannot generate detailed three-dimensional tissue maps. Newer microscopic imaging techniques offer better resolution but are plagued by slow measurement speeds. Consequently, these scans are highly vulnerable to errors caused by natural patient movements like breathing or involuntary eye twitches. Furthermore, current high-resolution tools rely on calibration materials that fluctuate with environmental changes, compromising their diagnostic accuracy.

Technology

This optical mapping system evaluates the structural health of a patient’s cornea by combining rapid Brillouin spectroscopy with precise three-dimensional motion tracking. The technology non-invasively collects measurements from various depths and lateral positions within the eye to create accurate 3D maps of corneal biomechanics. An optimized spectrometer speeds up the scanning process threefold, while a high-resolution tracking system continuously compensates for involuntary eye movements and breathing. Furthermore, the system employs an atomic gas absorption method for frequency calibration, ensuring exceptional measurement reliability to detect early-stage corneal disorders like subclinical keratoconus.

What sets this technology apart is its ability to map localized tissue strength without physically deforming the eye. Traditional devices rely on air puffs to measure mechanical responses, which are often skewed by the entire eye’s structure, fluid pressure, and corneal thickness. While other optical techniques struggle with motion artifacts, this system directly probes specific tissue properties at a microscopic level. The integration of rapid 3D tracking effectively eliminates motion-related errors, and the unique gas calibration avoids the environmental vulnerabilities of standard reference materials, offering unprecedented precision for clinical diagnostics and post-surgical monitoring.

Benefits

  • Enables early and accurate detection of subclinical keratoconus and localized biomechanical changes following refractive surgery.
  • Provides non-invasive, high-resolution 3D mapping of corneal biomechanics without the need to physically deform the eye tissue.
  • Reduces measurement time threefold, significantly improving patient comfort and minimizing the overall procedure duration.
  • Incorporates high-precision 3D motion tracking to effectively compensate for involuntary patient movements (such as breathing or eye shifting), ensuring exceptional spatial accuracy.
  • Delivers highly reliable, MHz-level spectral accuracy through atomic gas absorption calibration that remains stable regardless of environmental conditions.
  • Isolates the specific biomechanical properties of the cornea, avoiding confounding factors like intraocular pressure, corneal thickness, or whole-eye mechanical responses that limit traditional devices.

Applications

  • Early detection of keratoconus
  • Pre-operative refractive surgery screening
  • Post-surgical corneal ectasia monitoring
  • 3D corneal biomechanics mapping
  • Monitoring corneal disease progression

Additional info

This system integrates high-speed Brillouin microscopy with micron-scale 3D motion tracking and atomic gas absorption calibration. It non-invasively maps corneal longitudinal modulus by collecting depth-dependent spectral data. The optimized spectrometer reduces measurement time threefold, while the tracking system compensates for patient movement with 3 μm axial precision. This enables accurate, high-resolution 3D biomechanical profiling to detect subclinical keratoconus and monitor post-surgical corneal stability.